Ae2 me controller max size. 19. Ae2 me controller max size

 
19Ae2 me controller max size  manually mine

7. You configure the connections by using the ME Bus Memory Card; First Shift+Right Click the input to save it on your memory card, then simply right click the diffrent outputs to store the input onto the. Glass, Covered and Smart cables all support 8 channels. Manages a single auto crafting task from start to finsh, built of various crafting units. As long as you dont need AE2 crafting on that side, use the logistic pipes remote ordere +. like it doesnt exist. MEコントローラ (ME Controller) スカイストーンブロック:4+純粋なフルーシュクリスタル:4+上級プロセッサ:1. Key things to remember about channels: Each side of a controller block can support 32 channels. Refined Storage vs Applied Energistics 2 for displaying a. The developers of the pack have turned off AE2's channel system, if you'd like to re-enable it, consider the following: Find modpack's files -> Open config folder -> Find "AppliedEnergistics2. 4 4.MEネットワークを構築する. 0. It is the main part of any ME Network which handles everything like a CPU does in your computer. r/feedthebeast. Applied Energistics 2; Main File 1. That's 32x32 channels (1,024) going through a single dense cable line. Or so I heard. • 4 yr. Join. As far as I am aware those are the only restrictions. Craft a Network Tool (think that is the name) and right click on something AE2 related with it. 1. LP was available very early on and with almost default recipe, was able to do pretty much everything AE2 can (just with a significant speed and size disadvantage), and even had integration with AE2 to make transitioning between them easier (literally a pipe to an ME Interface and the LP system could access the storage of the ME System, so you. AE2 ME system Issues. The only way to kick-start it seems to be breaking parts of the ME controller up and placing them back down. It is the new and overhauled version of the original Applied Energistics mod. It accepts energy in from most sources, such as EU and MJ and provides it to the machines connected to it. Make sure that none of the cables of the same colors attach to each other, use different colors for cables and do not attach fluix cables directly to the. 超圧縮し省スペース化を実現する大容量チェスト、洗練されたアイテム輸送等、 貯蔵&輸送 に特化した装置を追加する。. 2. . them outside the network. Controllers can have maximum of 2 adjacent blocks in at most 1 axis (the cannot have a plus sign rule). 生産 :40AE/t. (MAs), and to surround your Interfaces with 6 MAs each (like most AE2 blocks, MAs do transfer channels). SSD can have as many of these ad-hoc networks as you want. The storage cell can be formatted before use to only accept certain items in the Cell Workbench. Required Tool. i would suggest using a RFTools crafter to do a passive autocraft to keep stock of each level of essence (using drawers or something) as opposed to. In-world configuration has an adapter touching an export bus and an ME controller, and has a database upgrade in the adapter. (For instance Import/Export/Storage Buses, ME Drives or Chests, P2P Tunnels, etc. Reasons why it should be considered Symmetry - fans would be happy. Controller mutliblock has to fit within a 7x7x7 - again, not too bad. 771. i currently have 2 energy acceptors connected to the same glass cable, and the. Last modified on 03/09/2014 10:04 PM CDT. The drives will act a bit weird until you get all the tunnels configured with your memory card. Replace your RF power generator with a power acceptor from AE2. An ME System is a system in Applied Energistics 2 that uses a ME Controller and a combination of other items found in Applied Energistics 2. them outside the network. One thing you will need to know when making a multiblock is that each controller can touch no more than 3 other controllers to remain valid. This is a great feature. Each block may have 2 adjacent blocks in at most 1 axis - this is the tricky one. Read below for info and updates on the s. To set up a network there are only a few things needed: exactly one ME Controller (it won't work if you have more) a power source connected to your Controller. Items like the Interface, Import Bus, ME Drive block, etc all consume 1 channel per device. 채널은 한 ME 네트워크에 연결 가능한 최대 기계 수로, 기본적으론 8채널만 지원한다. If you have Immersive Engineering, you can get a mod, called ZettaIndustries, that has ME cables which can span a long way and give you stable connection through unloaded chunks. (6) some EnderIO energy conduits for the power supply (if you want to be compact - they can share the space with the item conduits)OMFG THXS I loved ae1 and was heart broken when ae1 didn't get updated to 1. D:powerUsageMultiplier= used to adjust power requirements on all of ME tech, muliplied by base costs durring calculations. I've read similar problems posted on this subreddit and. I have the same 5x5x5 controller working just fine on FTB Revelations as well so it isn’t a limitation that you’re running into. Or just do the level emitter thing, or external automated crafters and pre. Feed The Beast Wiki. Machines operate at max speed (resonant + the 3 speed upgrades). Place down the Storage Drawer, install the Void Upgrade, Lock the Drawer with the Item (or. I have a one-controller carrier network between a hollow 3x3 controller and my devices and I'm at 140 channels without breaking a sweat. Something to keep in mind is that, with the Type limit, you are encouraged to build more, smaller Storage Cells. All controllers on a network must be connected pretty self explanatory. When you create a P2P into a dense cable, you are converting 32 channels from 1 facing into 1 channel. 5 Some examples of sub-networks and their use . you can feed power into your network via an energy acceptor or using quartz cable (not fluix). If you want more than 8 devices on your network, you must have a Controller. Jan 15, 2015. 2. Since all the tunnels connect directly to the controller and are equal to a length 1 hop, the channels will never route sideways through the machines. Additional channels can be added to network via placing additional controllers adjacent to current controller (with a few structure rules) Dense lines from each side must be completely independent of another, or else the network interferes. In AE2 the ME Interface is basically instantaneous, so it should be limited by whatever is pushing the items into it. Cheers! The ME Controller is a block added by the Applied Energistics 2 mod. The ME Network is a multi-block structure added by the Applied Energistics 2 mod. To follow up on this, a popular alternative is called Refined Storage, and it can be simpler for new players. More posts you may likeDrawer A. Alternative, use a level controller pointing to the machine or an export bus/interface with a crafting card set to make the item you want. networkfeatures {. An instant connection between any two points on an ME Network. 14 others) automatic. You can throw item into the storage scanner, pull items out, and craft in it from all nearby inventories. Applied Energistics 2; Energy, Fluid, and Item Transport; Addons; Storage; Main File 1. extenders= the maximum number of wireless boosters ( capped at 64 ). 3 sides total of 24 channels instead of using 4 sides using 4-6 channels. The ME Controller can only have 3 neighbors, as Nonsanity mentioned in his video, which I highly recommend you. Blocking mode for sub-networks point main network toward sub net for 1:1 or point sub networks toward the main interface for up to 5 sub networks per interface. 2) Wire the 5 p2p ends from the other side, the top 2, and the top 1 on the back side. A Network requires power, which can be provided by various blocks, and may require ME. The current AE2 developer has said that he does not want the storage system to be a power provider. More info below!You can support me and the channel! Read more here: my first base I set up a 5x5 big reactor which was my power source for rf machines and ae2. you are also advised to use storage drawers with ae2. Unlike the ME Chest, the items that are stored inside the storage cells cannot be directly accessed; instead the drive must be connected to a ME Network which allows. I then use an Ender IO power monitor to turn the reactor on and off. Once the system detects named item 1 has finished it’ll put it and the next 8 components and named item 1 into the chest. Without the limit on channels, the ME Controller offers no bonuses over the power acceptor (besides looking cooler). So, i am now at the point where i need/want a multiblock ME controller. Almost right. 1 Definitions and conceptual implications . All ME Controller blocks on a ME Network must be connected; else the blocks will turn red. Channels are just a funny way to say bandwidth. It’s literally one output for a channel. Aug 20, 2015. I tried using Energy Acceptors but that didn't work to bridge the cap. ago. 12. I didnt recognize the vibration chamber. 2. 57. A "Sub-Network" is a separate ME Network that augments another network. The only recent modification was the addition of 2 more vertical levels on the casters. The Drawer Controller is a block added by Storage Drawers. B:PowerGen=. It would be nice to be able to simply configure each item using the ME Interface, so that only a. Configure the interface. the energy acceptor is now passing power to the main network, which is passing it to. All others (max. . All Spatial Pylons must be either connected with cable or via a QNB, and on the same network. But it also means that they connect even if you don't want them to and you can get cross connections. ME Storage Cell are used to store items; for example, possessing a 64k ME Storage Cell allows the player to store up to. The ME Dense Cable is the only cable that can support 32 channel simultaneously so it can be used as a main data line to connect to another ME Controller or branch off into 8 channel. For every 32 drives, you'll need one P2P tunnel on the controller. (note i don't have AE2 installed, so imagine the glass is an assembler and the iron is the interface) The ME Controller is the brain of your ME system. Channels are a limiting factor on how big an AE network of devices can be. According to my own calculations, the maximum amount of items you can store is somewhere are 20,000,000. When taken by itself, the ME Controller does nothing. I've been playing on my E2E on and off for about a year now, and I recently decided to upgrade my base and AE2 ME system setup. One dense cable gives 32 channels, which is enough to autocraft 288 items (9 items per interface; molecular assemblers don't require a. CurseForge is one of the biggest mod repositories in the world, serving communities like Minecraft, WoW, The Sims 4, and more. Technicaly it doesn't, but it's the only way to get the max channels out of many shapes of controllers. Remember that AE devices link to each other and connect to the network. 0:00 / 9:22. In total: 22816 channels through P2P tunnels, but there are a few more that I forgot when I recorded the video. 2; AE2 Version: appliedenergistics2-rv6-stable-6 A futuristic block of chisel has the exact same texture as the AE2 Controller, just use them to make the shape you want and add the controllers you need ^^. . Because the ME Controller has a limited surface area, therefore a limited number of channels, u/prozacgod came up with the idea of using a specific shape that has a large surface area that fulfils the maximum size of an ME Controller. If it's ok, cancel and double it, try again. 5% energy tax is deducted as transfer loss. A 4k disk is 4x the size and cost of a 1k disk and the index is 4x bigger. The main feature of Applied Energistics 2 is the ME Network ( pronounced Emm-Eee and stands for Matter Energy ), which is a set of connected blocks, and cables grouped into a system, where storage, power and functions cooperate between multiple components. 0 [1. Functional Storage is an alternative take on the storage solution of Storage Drawers, with an updated look and additional functionalities like: Armory Cabinet: It stores 4096 non stackeable items (by default) and can only be accessed with external tools (currently) like Applied Energistics or Refined Storage external storage tools. 5. any rf/fe source can be used (either hooked up to the controller or an energy acceptor) Reply replyInscribers can go die in a fire. As long as all rules are followed and powered, the controller should glow and cycle colors. Applied Energistics 2 (AE2) is a mod for Minecraft that adds advanced storage and automation systems to the game. So putting some thoughts into it will certainly reward more compared to a quick solution. There's three rules with. :D. The main feature of Applied Energistics 2 is the ME Network ( pronounced Emm-Eee and stands for Matter Energy ), which is a set of connected blocks, and cables grouped into a system, where storage, power and functions cooperate between multiple components. The first tier of AE2 tech, such as the , Certus Quartz Wrench, Certus Quartz Cutting Knife, and Certus Quartz tools, uses Certus Quartz as the primary crafting ingredient. You make a me controller, a drive, and an access terminal, make a storage disk, place all machines next to each other, power the me controller with some form of mj or eu power. This device also requires a large amount of power to operate. If you hook that up to any storage and connect it to your your system all the items in said storage will now be visible to the system. The only catch is that you have to run a separate p2p tunnel to access the auto crafting capabilities. The Charger is a machine added by Applied Energistics 2. I usually have 2 dense cable coming out from the controller, that's face for connecting p2ps. 94. size unless you do something like the last pic. ME Controller · ME Power Relay. 大容量チェストMODとして. Edit 2: I solved it! I don't know what it was that was causing the items to disappear but I just tore out all the ME controllers and replaced each cable connection one by one to try and find the one causing the problem, but after I did that it just went back to normal. • 18 days ago. The amount of Coal Ore produced by a Void Ore Miner is obscene. クリスタル成長加速機. Featured playlist. Storing an item however always takes the same amount of space, regardless of the drive. This video covers the basic workings of Applied Energistics 2 related to Cables, Channels and Controller. (MAs), and to surround your Interfaces with 6 MAs each (like most AE2 blocks, MAs do transfer channels). The ME Controller has a maximum length of 7 blocks total B. Dense, P2P and Quantum Ring all support 32 channels. To use - place 2 Wireless Connectors and right click both with a Wireless Configuration Kit. First Appearance : MC 1. Whenever you have more than 8 devices in a network, an ME Contr. Top 3% Rank by size. You can deduct the inputs though, if they start from another side of the ME controller. This is okay when dealing with busses, interfaces, and molecular assemblers. toml): DisableChannels (initially -> false) - disables channel restrictions; ControllerLimits (initially -> false) - allows you to install several controllers in the same network. . This means you can output to as many points as you want, but only input at a single point per tunnel. The test now included a controller, import bus, a storage block (I tested a few, same results, one being modded, the black hole unit from IF), cryotheum flux ducts and capacitor banks. AE2 cables do not have a distance restriction, they have a connected device restriction, called "channels". 7. Medium Spatial Cell which can store 16x16x16 regions of space. 1 Proper AE2 System Design Rules: 1. 1. You shouldn't configure anything else on the storage bus. What I don't like about AE2's CPU is you need 3 parts: the CPU, an ME interface, and a molecular. Each face supports 32 channels. 4-rv6-stable-7. If you’re having trouble executing the mod, try reading this article of ours that teaches mod implementation for Minecraft. I was very well versed with AE1 and often had huge networks with lots of crafting abilities. toml): DisableChannels (initially -> false) - disables channel restrictions; ControllerLimits (initially -> false) - allows you to install several. Blue is RF into (into the LEC), orange is. 6 6.バニラのチェストとアイテムの受け渡し. Here's something that uses. 2; Forge; Nov 7, 2023;. It allows items to be inserted into or extracted from the ME System it is connected to. 12. Each block has a placed or gap state, so 2 ^ 343 = 1. For example, RF to/from EU. . This mod is server side only. The structure must be an ME network with a number of Spatial Pylons which define the target region. 1 チュートリアル. A Sky Factory 4 Tutorial on how to setup a basic Applied Energistics ME System. To configure a P2P Tunnel you must first attune the tunnel to carry what you want it to, then you need to configure the outputs to their input. will post updates on free time to show my advancement in the base. I:max. Depends on what you're running though. 20, AE2 offers an in-game guide. Also, AE2 uses priorities intelligently. I've tried. size unless you do something like the last pic. Make a doughnut shaped controller multiblock with 8 controllers. But what is interesting is that the "other side" of the P2P interface is actually managed like a second distinct ME network multiblock. If an ae2 system is powered through an energy acceptor but has no controller it can support up to 8 channels. The mod's Energy Acceptor and Controllers accepts both Forge Energy (FE, RF, µI, CF, IF, etc. 1) Wire the 5 p2p ends from one side, the bottom 2, and the bottom 1 on the back side. Aesthetically, the AE1 CPU was bigger, which made it look cooler as the centerpoint of a base IMO. Edited to include versions (Minecraft 1. Disble chanels limit; And settings for all upper; Setting for conroller max size; Setting for amount of item and fluid per byte . A single block controller could take in 3 dense cables and output 3 dense cables, meaning you would have access to 3 * 32 * 32=3072 channels from a single block controller. More posts you may like. アイテムをデジタルデータ化して貯蔵、運用するといった趣のMOD。. Well, maybe wrong cuz I'm still learning AE2 but it is definetely much larger than just 32 channels :pThe item you are looking for is the "external storage" (RF) / "Storage bus) (AE2). Many mods also offer a similar feature, but all i know of are worse and meant for earlier in progression than AE2. . Ae2 and drawers are compatible. They are capable of transmitting 32 channels, which you can expand. (Crystal Growth Accelerator) 鉄インゴット:4+MEガラスケーブル - フルーシュ:2+クォーツガラス:2+フルーシュブロック:1. The ME crafting terminal from ae2 tutorial. E. it can be hollow, but be careful, some of the outer ones will deactivate, you will have to add holes. Each side of ME controller provide 32 channels. This structure can be built in any cuboid, or size as long as the following Criteria are met. The maximum length of one axis of the multiblock is 7 blocks; An ME Controller can have 2 adjacent blocks in at most 1 axis; Rule #3 essentially means that, of the 3 axes (north/south, east/west, up/down), only one of those axes can have 2 controller blocks on both sides of any given controller and that the other axes may only have one. It is the new and overhauled version of the original Applied Energistics mod. Just put one ME Storage Bus on the Drawer Controller. 18. There can only be one on a single network, if you put multiple the whole network will lock up, and the controllers will turn red. The ME Quantum Network Bridge device is a multiblock unit capable of connecting distant ME networks together. No crafting recipe for the AE2 version only chisel. Construct a basic AE network (tested with a single AE controller connected to a creative energy cell and an ME chest with a 64k storage cell in it) attach adapter to ME controller and computer; Place 2 diamond swords in. In that setup each interface was adjacent to at least 3 assemblers, which was the max a Crafting CPU with no co-processors could utilize. Hello, want to know why the MB limit is 17x17x17? This a max amount of 314. Every machine in AE2 takes up 1 channel. Replace VERSION with the desired one. A big part of the struggle on the configuration shown is the reupdate + Light recalculation as ME Controller emit lights when on. Setting the Storage Bus to a high priority should be all you need to ensure items always go there first. In IC2, the basic solid-fuel burning Generator produces 10 EU/t, and the most end-game generator (Liquid Cooled Reactor) can produce about 1,000 EU/t. Without a controller, an ME network can handle only up to 8 channels, with a controller it can handle more (well, 32 per side of the controller, as usual). An updated guide on large ME controllers and P2P networking. . 2 One route to the controller: 1. I don't really get this current trend. So the system keeps flickering on and off, we have no current power issues, I thought it could have been not enough power in the system so I added 3 cells, it didn't fix it, I. Void junk/non stackable items or store. all sides of the controller are fully functional and plugged in to each other creating one massive controller with the ability to add more sections if i need more channels. 1. Thats why you need the cells, they increase your Maximum rf storage, and therefore your maximum possible. To set up a network there are only a few things needed: exactly one ME Controller (it won't work if you have more) a power source connected to your Controller. The ME Wireless Access Point is a block added by the Applied Energistics 2 mod. I just use a normal reactor with a huge capacitor bank to store power. That means it can transfer 16krf/t. This shape, a fractal called a Hilbert Curve, has the largest known number of. I agree, you can pretty much do everything a well equipped base needs with 1 controller and a few dense cables (or p2p, if you want). Get the configuration of the interface. If the ME controller hub is working fine, then attached your p2p to one face first of the hub thats powered and the other p2p to the location. anabsolutesloth • 4 yr. modsフォルダの中に、ダウンロードした Lazy AE2 を jarファイルのまま コピー&貼り付けする. If you make the line the p2p ports are on connect to a controller, you can also connect the p2p face of the p2p port onto the same controller, allowing you to use the controller to connect. The p2p network by itself is a normal ME network (with the one difference that it connects p2p tunnels instead of storage/crafting devices etc. An updated guide on large ME controllers and P2P networking. One side of the me controller. using an AE2 inscriber to make stamped plates). Also a 3x3 square would not work due to the way they work. 容量 :8,000AE. An ME Controller can have 2 adjacent blocks in at most 1 axis Rule #3 essentially means that, of the 3 axes (north/south, east/west, up/down), only one of those axes can have 2 controller blocks on both sides of any given controller and that the other axes may only have one controller after that. Applied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). I think this might give more channels per controller (128 per controller vs 124) but I might be wrong. 8 in normal cables. (3) 5 inscribers. I:max. The Controller will need power to work. 4kRF) and i can't seem to get any more energy into the system with energy acceptors. How to make the inscriber, processors, fluix crystals, and complete setup. Maximum size of the ME Controller multiblock is now configurable. The bus priority should be extremely high, set it to 10000 to be positive. Most devices such as standard cables, and machines can only support up to 8 channels. 10 ae2 was just to annoying and it felt as if they ruined my favourite mid but thank you for this post cause I like the concept of everything ae2 stands for like the inscribed and meteorites to make things but growing certus and channels mad me think wtf did he do. 超圧縮し省スペース化を実現する大容量チェスト、洗練されたアイテム輸送等、 貯蔵&輸送 に特化した装置を追加する。. The mod is free and you can download it here. A creative build where I tried to max out an ME Controller, to get as many channels as possible available for usage. When your networks starts to grow, so must your ME Controller. malicious_bloke. At the moment, my ME System is located underneath my Incense Altar Pyramid (Max size), but I am considering moving after I find a new base location. It is part of Applied Energistics 2, a mod to digitalize storage and automate machines. To summarize what everyone else is saying: if you want a "vanilla" AE2 solution use a quantum bridge otherwise, if you want to extend your System to the. Yeah what you found is actually a main part of "normal" ae2 progression, the ad hoc system. Today we will. . Von den neuen R. Got 2 Mekanism ore quadrupling setups but they aren't running constantly. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright. An RS system will cause more lag than an AE2 system that's 4 times the size. ago. Quantum Field Ring. The CPU must contain at least 1 storage component. This allows the mod (Applied Energistics 2) to accept multiple forms of power, but not be a totally broken power converter. 3. There is a way to circumvent this. The channels documentation states controllers still reduce power consumption with infinite channels, so I added some controllers to our network. Applied Energistics 2: ID Name : appliedenergistics2:item. The power source is a vibration chamber, i assumed it didnt need a power acceptor since it have ae directly. The ME Terminal is an item added by the Applied Energistics 2 mod. 2 2.グラインドストーンを作る. Type. A couple facts: Each side of the controller can handle up to 32 channels. One actively pulls items, one passively accepts items. If an internal link led you here, you may wish to change the link to point directly to the intended article. ME Controllers output 32 channels per side. If you want some kind of storage- which in. 32 in dense ones. When right clicked, the Controller's GUI will display the state of the controller, the total energy stored, the energy draw of the network, and the devices connected to the ME Controller in the center (Note. 適切に隣接させるとマルチブロックになる。. . AE2 current setup. Configuration file (ae2ao. jar. Install the highest level of storage upgrade that you can on the drawers, and a void upgrade (which will delete anything going to a drawer that is. Applied Energistics 2's ME Networks require Channels to support devices which use networked storage, or other network services. Set the level controller to 1000 torches and point it at an export bus for torches with a crafting. A creative build where I tried to max out an ME Controller, to get as many channels as possible available for usage. Added GTEU p2p. ME Controllers output 32 channels per block face, so one singular controller has 6 faces x 32 channels = 192 total channels. when cheated it on online server or local/single player it acts like a 'stone block' its possible to edit it with the chisel and it becomes another block (like the chisel mod works) Minecraft Version: 1. com, stoneblock version is 1. The mod includes a network-based storage sy. The Compacting Drawer is a block added by Storage Drawers to quickly convert items between Storage Blocks and their original form. AE2 rv3 beta6. Controllers are a free-form Multiblock with various build rules. Applied Energistics 2 (AE2) is a mod for Minecraft that adds advanced storage and automation systems to the game. Add a Comment. D:powerUsageMultiplier= used to adjust power requirements on all of ME tech, muliplied by base costs durring calculations. AE2 Network Tool GUI. ME Controller • ME Covered Cable. One side of an ME controller can provide a bus for 32 systems. Also, AE2 uses priorities intelligently. The controller is a multiblock structure that follows a few. 2 Vanilla+ modpack for people who would just like to take it slow and enjoy a nice, cohesive and consistent experience! 380. manually mine. I don't know if I can change the flair to. The ME Controller is a multiblock structure, the minimum being 1x1x1 and the max being 7x7x7. On Thu, Feb 18, 2016 at 3:13 PM TTLPcraft notifications@github. When I expanded it I searched for a way to have 32 interfaces on one ME Dense Cable. To increase the amount of channels able to be used install a ME Controller (Applied Energistics 2). • 18 days ago. We also review how ME Controllers connect. [deleted] • 7 yr. An ME interface allows you to pump things into it. 2 In Conclusion . ME Cable can also be colored with dyes. • 1 yr. 1. I wanted to build a 30x10xn (n = 3 or more layers) but after I place the 18th bl. ME Storage Cell are used to store items; for example, possessing a 64k ME Storage Cell allows the player to store up to. (ME interface, screens, autocrafters, anything) Each side of your ME Controller block has 32 available channels. but thats buggy isnt it ? Theoretically the max size of a ME system depends on the number of faces of your controller you can access and extract channels from. There can only be one on a single network, if you put multiple the whole network will lock up, and the controllers will turn red. Server address is sb. 11. It has to be touching the drawer bank. B. The mod allows you to: Remove channel restrictions; Connect controllers via cable; Expand or shrink maximum multiblock size from controllers. ME Drives are a device in Applied Energistics 2 which allow users to store up to 10 ME Storage Cells as opposed to a single cell that can be placed in a ME Chest . at least one Storage Block (ME Drive or ME Chest) The following are rather optional. That seemed to be the problem, I got my me system working again, I just had to remove and change some cables, thx. 12. I have a question regarding AE2. Applied Energistics is a Minecraft Mod which contains an advanced storage system called ME that lets you store items compactly and in the way you want, as well as do intricate automation. As far as exceeding the 7-consecutive-controller-blocks restriction is concerned, I think its hard coded, although you CAN turn off channels in the config file (networkfeatures field) - if your goal is just to have more channels. P2P tunnels are always set to 1-to-n. I found an old bug report (5 years ago) about me multiblocks chunk loading, so I isolated the controllers. Top: Double-compressed item Lower-left: Compressed item Lower-right: Base item Extracting is performed with the left mouse button. Here is a little breakdown of how I wired it. I have yet to see a significant bonus to using 16k's or 64k's. Energy efficiency. Raspberry Flavoured, a 1. AE2 Auto-crafting becomes a balancing act between speed and efficiency, while also having to keep channels in mind.